Product

10kW - 16kW Generac Generator Wire / Aluminum PART#10AL

In stock

STARTING AT $8.18 THE PRICE PER FOOT DECREASES AS LENGTH INCREASES. CHOOSE LENGTH TO SEE YOUR TOTAL SHIPPED PRICE.

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537 Max length of 115' recommended

**This Multi Conductor Cable includes the following stranded Aluminum conductors: Three #3AWG - One #6AWG - Also includes Nine Copper #18AWG

**This is an all-inclusive cable that includes all conductors necessary to connect your generator to the transfer switch. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**The 16AWG control conductors allow this cable to be used at longer lengths. All NEC mandates about voltage drop on all current carrying conductors must be adhered to.

**Not all jurisdictions consider aluminum conductors an acceptable wiring method. Please confirm with your Authority Having Jurisdiction prior to purchasing this cable.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED

250' ORDERS NORMALLY TAKE 7-10 DAYS TO LEAVE FACTORY - THIS IS NO GUARANTEE - WE ARE UNABLE TO PROVIDE TRACKING OR CHECK LEAD TIMES ON 250' ORDERS

Additional $75.00 shipping fee may apply for residential or lift gate service on 250' orders

Generator 10kW - 16kW Generac Aluminum Generator Wire /  Technical Specs:

Click Here To See Spec Sheet

Wire Outer Diameter = .980"

WIRE JACKET PRINT LEGEND:  (UL) E60544-PA POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 3 AWG (26,7 mm2) 3/C + 8 AWG (8,37 mm2) 1/C
GROUND THWN CONDS 75C DRY/75C WET & 18 AWG (0,82 mm2) 9/C TFFN CONDS 600V OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL PN TCERJP 1724G+2 "sequential footage print"

 

Components

COMPONENTS: A: (3) - #3 AWG Class B stranded, 8000 series, aluminum conductors w/40 mils (1.016 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 6 mils (0.15 mm) nylon applied directly to the surface of the insulation.

B: (6) - #16 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.

C: (1) - #6 AWG Class B stranded, 8000 series, aluminum conductor w/30 mils (0.76 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the surface of the insulation

D: Mylar binder tape.

E: 80 mils (2.03 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket.

The 2017 NEC, allows this wire to be installed without a conduit or flexible raceway unless subject to physical damage. Consult with your authority having jurisdiction prior to installation.

Associated to Generator Models: 7223, 7224, 7225, 7171, 7172, 7173, 7174, 7175, 7176, 7177, 7178, 7031, 7032, 7033, 7035, 7036, 7037

Description

STARTING AT $8.18 THE PRICE PER FOOT DECREASES AS LENGTH INCREASES. CHOOSE LENGTH TO SEE YOUR TOTAL SHIPPED PRICE.

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537 Max length of 115' recommended

**This Multi Conductor Cable includes the following stranded Aluminum conductors: Three #3AWG - One #6AWG - Also includes Nine Copper #18AWG

**This is an all-inclusive cable that includes all conductors necessary to connect your generator to the transfer switch. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**The 16AWG control conductors allow this cable to be used at longer lengths. All NEC mandates about voltage drop on all current carrying conductors must be adhered to.

**Not all jurisdictions consider aluminum conductors an acceptable wiring method. Please confirm with your Authority Having Jurisdiction prior to purchasing this cable.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED

250' ORDERS NORMALLY TAKE 7-10 DAYS TO LEAVE FACTORY - THIS IS NO GUARANTEE - WE ARE UNABLE TO PROVIDE TRACKING OR CHECK LEAD TIMES ON 250' ORDERS

Additional $75.00 shipping fee may apply for residential or lift gate service on 250' orders

Generator 10kW - 16kW Generac Aluminum Generator Wire /  Technical Specs:

Click Here To See Spec Sheet

Wire Outer Diameter = .980"

WIRE JACKET PRINT LEGEND:  (UL) E60544-PA POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 3 AWG (26,7 mm2) 3/C + 8 AWG (8,37 mm2) 1/C
GROUND THWN CONDS 75C DRY/75C WET & 18 AWG (0,82 mm2) 9/C TFFN CONDS 600V OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL PN TCERJP 1724G+2 "sequential footage print"

 

Components

COMPONENTS: A: (3) - #3 AWG Class B stranded, 8000 series, aluminum conductors w/40 mils (1.016 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 6 mils (0.15 mm) nylon applied directly to the surface of the insulation.

B: (6) - #16 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.

C: (1) - #6 AWG Class B stranded, 8000 series, aluminum conductor w/30 mils (0.76 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the surface of the insulation

D: Mylar binder tape.

E: 80 mils (2.03 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket.

The 2017 NEC, allows this wire to be installed without a conduit or flexible raceway unless subject to physical damage. Consult with your authority having jurisdiction prior to installation.

Associated to Generator Models: 7223, 7224, 7225, 7171, 7172, 7173, 7174, 7175, 7176, 7177, 7178, 7031, 7032, 7033, 7035, 7036, 7037