--- End Ad block --->

Product

10kW - 16kW Generac Generator Wire /Generator Purchase Add On (Aluminum)

In stock

THIS PRICING IS ONLY AVAILABLE WHEN PURCHASED AND SHIPPED WITH A GENERATOR!   CLICK HERE TO PURCHASE THIS WIRE SEPARATELY!

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537

**This Multi Conductor Cable includes the following stranded Aluminum conductors: Three #3AWG - One #6AWG; It also includes the following stranded Copper conductors: Nine #18AWG;

**This is an all-inclusive cable that includes all conductors necessary to connect your generator to the transfer switch. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**The 16AWG control conductors allow this cable to be used at longer lengths. All NEC mandates about voltage drop on all current carrying conductors must be adhered to

**Not all jurisdictions consider aluminum conductors an acceptable wiring method. Please confirm with your Authority Having Jurisdiction prior to purchasing this cable.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED 

Generator 10kW - 16kW Generac Aluminum Generator Wire /  Technical Specs:

Click Here To See Spec Sheet

Wire Outer Diameter = .980"

WIRE JACKET PRINT LEGEND:  (UL) E60544 POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 3 AWG AL (26,7 mm2) 3/C + 6 AWG AL (13,3
mm2) 1/C GROUND THWN CONDS & 16 AWG (1,31 mm2) 6/C TFFN CONDS 600V 75C DRY/75C WET OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL GENERAC P/N AL TCERJP0713 "sequential footage print"

COMPONENTS: A: (3) - #3 AWG Class B stranded, 8000 series, aluminum conductors w/40 mils (1.016 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 6 mils (0.15 mm) nylon applied directly to the surface of the insulation.

B: (6) - #16 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.

C: (1) - #6 AWG Class B stranded, 8000 series, aluminum conductor w/30 mils (0.76 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the surface of the insulation

D: Mylar binder tape.

E: 80 mils (2.03 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket.


Associated to Generator Models: 7223, 7224, 7225, 7171, 7172, 7173, 7174, 7175, 7176, 7177, 7178, 7031, 7032,7033, 7035, 7036, 7037

Description

THIS PRICING IS ONLY AVAILABLE WHEN PURCHASED AND SHIPPED WITH A GENERATOR!   CLICK HERE TO PURCHASE THIS WIRE SEPARATELY!

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537

**This Multi Conductor Cable includes the following stranded Aluminum conductors: Three #3AWG - One #6AWG; It also includes the following stranded Copper conductors: Nine #18AWG;

**This is an all-inclusive cable that includes all conductors necessary to connect your generator to the transfer switch. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**The 16AWG control conductors allow this cable to be used at longer lengths. All NEC mandates about voltage drop on all current carrying conductors must be adhered to

**Not all jurisdictions consider aluminum conductors an acceptable wiring method. Please confirm with your Authority Having Jurisdiction prior to purchasing this cable.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED 

Generator 10kW - 16kW Generac Aluminum Generator Wire /  Technical Specs:

Click Here To See Spec Sheet

Wire Outer Diameter = .980"

WIRE JACKET PRINT LEGEND:  (UL) E60544 POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 3 AWG AL (26,7 mm2) 3/C + 6 AWG AL (13,3
mm2) 1/C GROUND THWN CONDS & 16 AWG (1,31 mm2) 6/C TFFN CONDS 600V 75C DRY/75C WET OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL GENERAC P/N AL TCERJP0713 "sequential footage print"

COMPONENTS: A: (3) - #3 AWG Class B stranded, 8000 series, aluminum conductors w/40 mils (1.016 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 6 mils (0.15 mm) nylon applied directly to the surface of the insulation.

B: (6) - #16 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.

C: (1) - #6 AWG Class B stranded, 8000 series, aluminum conductor w/30 mils (0.76 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the surface of the insulation

D: Mylar binder tape.

E: 80 mils (2.03 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket.


Associated to Generator Models: 7223, 7224, 7225, 7171, 7172, 7173, 7174, 7175, 7176, 7177, 7178, 7031, 7032,7033, 7035, 7036, 7037