10 Wire Control - Generac Generator Wire / Generator Purchase Add On (Copper) Part#10AOCUCONTROL

In stock

THIS PRICING IS ONLY AVAILABLE WHEN PURCHASED AND SHIPPED WITH A GENERATOR!  CLICK HERE TO PURCHASE THIS WIRE SEPARATELY!

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537

**This 10 Conductor Control Cable includes the following stranded copper conductors: TEN #18 awg. Conductor Color Code: Black, White, Red, Green, Yellow, Blue, Purple, Yellow/Black, Purple/Black, White/Blue   

**This dark GREY control cable includes TEN #18 awg conductors necessary to connect your generator to the transfer switch. THIS CABLE DOES NOT INCLUDE CURRENT CARRYING CONDUCTORS. YOU WILL HAVE TO SUPPLY AND INSTALL SEPARATELY. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED

Wire Outer Diameter = .460"

Click Here To See Spec Sheet

10 wire control cable / Technical Specs:

Wire Jacket Print Legend:
(UL) E60544 POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 18 AWG (0,82 mm2) 10/C TFFN CONDS 600V OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL TCERDirect.com PN TCERJP XXXXX "sequential footage print"

Components
A: (10) - #18 AWG Class K (16 strand), soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.
B: Flame resistant non-hygroscopic fillers (as needed).
C: Mylar binder tape.
D: 45 mils (1.14 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket. A ripcord shall be placed
underneath the jacket.



Description

THIS PRICING IS ONLY AVAILABLE WHEN PURCHASED AND SHIPPED WITH A GENERATOR!  CLICK HERE TO PURCHASE THIS WIRE SEPARATELY!

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537

**This 10 Conductor Control Cable includes the following stranded copper conductors: TEN #18 awg. Conductor Color Code: Black, White, Red, Green, Yellow, Blue, Purple, Yellow/Black, Purple/Black, White/Blue   

**This dark GREY control cable includes TEN #18 awg conductors necessary to connect your generator to the transfer switch. THIS CABLE DOES NOT INCLUDE CURRENT CARRYING CONDUCTORS. YOU WILL HAVE TO SUPPLY AND INSTALL SEPARATELY. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED

Wire Outer Diameter = .460"

Click Here To See Spec Sheet

10 wire control cable / Technical Specs:

Wire Jacket Print Legend:
(UL) E60544 POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 18 AWG (0,82 mm2) 10/C TFFN CONDS 600V OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL TCERDirect.com PN TCERJP XXXXX "sequential footage print"

Components
A: (10) - #18 AWG Class K (16 strand), soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.
B: Flame resistant non-hygroscopic fillers (as needed).
C: Mylar binder tape.
D: 45 mils (1.14 mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket. A ripcord shall be placed
underneath the jacket.