17kW - 24kW Generac Generator Wire / Generator Purchase Add On (Aluminum) Part#17AOAL

In stock

THIS PRICING IS ONLY AVAILABLE WHEN PURCHASED AND SHIPPED WITH A GENERATOR  CLICK HERE TO PURCHASE THIS WIRE SEPARATELY!

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537

**This Multi Conductor Cable includes the following stranded Aluminum conductors: Three #1AWG - One #6AWG - Also includes Nine Copper #18AWG

**This is an all-inclusive cable that includes all conductors necessary to connect your generator to the transfer switch. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**Not all jurisdictions consider aluminum conductors an acceptable wiring method. Please confirm with your Authority Having Jurisdiction prior to purchasing this cable.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED 

Ziller Electric does not endorse this wire being used with a 26kW air cooled generator

Generator 17kW - 24kW Generac Aluminum Generator Wire /  Technical Specs:

Click Here To See Spec Sheet

Wire Outer Diameter = 1.13"

Wire Jacket Print Legend:

(UL) E60544-PA POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 1 AWG AL (42,4 mm2) 3/C + 6 AWG AL (13,3 mm2) 1/ C GROUND THWN CONDS 75C DRY/75C WET & 18 AWG (0,82 mm2) 9/C TFFN CONDS 600V OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL TCERDirect.com PN AL TCERJP 1724G+2 "sequential footage print"

Components

A: (3) - #1 AWG Class B stranded, 8000 series, aluminum conductors w/50 mils (1.27 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 7 mils (0.18 mm) nylon applied directly to the surface of the insulation.

B: (9) - #18 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.

C: (1) - #6 AWG Class B stranded, 8000 series, aluminum conductor w/30 mils (0.76 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the surface of the insulation

D: Mylar binder tape.

E: 1.80 mils (2.03mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket. A rip cord shall be placed underneath the jacket.

The 2017 NEC, allows this wire to be installed without a conduit or flexible raceway unless subject to physical damage. Consult with your authority having jurisdiction prior to installation.

Associated to Generator Models: 7226, 7228, 7038, 7039, 7042, 7043, 7209, 7210

Description

THIS PRICING IS ONLY AVAILABLE WHEN PURCHASED AND SHIPPED WITH A GENERATOR  CLICK HERE TO PURCHASE THIS WIRE SEPARATELY!

**Need more than 100' with your generator purchase? Call for pricing: 1-888-294-5537

**This Multi Conductor Cable includes the following stranded Aluminum conductors: Three #1AWG - One #6AWG - Also includes Nine Copper #18AWG

**This is an all-inclusive cable that includes all conductors necessary to connect your generator to the transfer switch. We recommend you measure the linear distance between the generator and transfer switch. The exact path the wire will be installed. Add 5' in length for connections within the generator and transfer switch.

**Not all jurisdictions consider aluminum conductors an acceptable wiring method. Please confirm with your Authority Having Jurisdiction prior to purchasing this cable.

**Many jurisdictions across the United States have their own rules, standards and interpretation of the NEC. You are responsible to confirm acceptance by your Authority Having Jurisdiction. See the spec sheet to provide them for approval. There are no returns or refunds once your order has been processed and the wire has been cut.

SALE OF CUT WIRE IS FINAL AND NO RETURNS WILL BE ACCEPTED 

Ziller Electric does not endorse this wire being used with a 26kW air cooled generator

Generator 17kW - 24kW Generac Aluminum Generator Wire /  Technical Specs:

Click Here To See Spec Sheet

Wire Outer Diameter = 1.13"

Wire Jacket Print Legend:

(UL) E60544-PA POWER AND CONTROL TRAY CABLE TYPE TC-ER-JP 1 AWG AL (42,4 mm2) 3/C + 6 AWG AL (13,3 mm2) 1/ C GROUND THWN CONDS 75C DRY/75C WET & 18 AWG (0,82 mm2) 9/C TFFN CONDS 600V OIL RES I SUNLIGHT RESISTANCE DIRECT BURIAL JOIST PULL TCERDirect.com PN AL TCERJP 1724G+2 "sequential footage print"

Components

A: (3) - #1 AWG Class B stranded, 8000 series, aluminum conductors w/50 mils (1.27 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 7 mils (0.18 mm) nylon applied directly to the surface of the insulation.

B: (9) - #18 AWG Class K stranded, soft drawn, bare copper conductors w/15 mils (0.38 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 4 mils (0.10 mm) nylon applied directly to the surface of the insulation.

C: (1) - #6 AWG Class B stranded, 8000 series, aluminum conductor w/30 mils (0.76 mm) heat and moisture resistant, polyvinyl chloride (PVC) insulation and jacketed w/ 5 mils (0.13 mm) nylon applied directly to the surface of the insulation

D: Mylar binder tape.

E: 1.80 mils (2.03mm) of heat and moisture resistant, polyvinyl chloride (PVC) jacket. A rip cord shall be placed underneath the jacket.

The 2017 NEC, allows this wire to be installed without a conduit or flexible raceway unless subject to physical damage. Consult with your authority having jurisdiction prior to installation.

Associated to Generator Models: 7226, 7228, 7038, 7039, 7042, 7043, 7209, 7210